Specifications
Measuring range: 20-88HRA, 20-100HRB, 20-70HRC
Test force: 588.4, 980.7, 1471N (60, 100, 150kgf)
Max. height of test piece: 400mm
Depth of throat: 160mm
Min. scale value: 0.5HR
Dimensions: 548 x 326 x 1025mm
Weight: approx. 140kg
Standard accessories
Large flat anvil: 1 pc.
Small flat anvil: 1 pc.
V-notch anvil: 1 pc.
Diamond cone penetrator: 1 pc.
1/16” steel ball penetrator: 1 pc.
Rockwell standardized block: 5 pcs.
HR-150B Heightened Rockwell Hardness Tester plays a very important role in the hardness test. Let us take a closer look at this product today.
Introduction:
HR-150B heightened Rockwell hardness tester, using the method of measuring the penetration depth, the hardness value is directly read by the indication.
Therefore, the operation is simple and convenient, easy to grasp, high work efficiency, and suitable for inspection of batch parts.
The Rockwell hardness test method can use diamond indenter and rigid ball indenter to measure hard and soft samples and has a wide range of applications. Therefore, the HR-150B Rockwell hardness test is widely used in production.
Detailed Introduction:
HR-150B heightened Rockwell hardness tester, using the method of measuring the penetration depth, the hardness value is directly read by the indication.
Therefore, the operation is simple and convenient, easy to grasp, high work efficiency, and suitable for inspection of batch parts.
The Rockwell hardness test method can use diamond indenter and rigid ball indenter to measure hard and soft samples and has a wide range of applications. Therefore, the HR-150B Rockwell hardness test is widely used in production.
It is the main means of testing to verify product quality and to determine a reasonable processing process.Rockwell hardness tester is the most commonly used test instrument for hardness testing and teaching and research work in production enterprises, universities and colleges.
Hardness tester scale:
A scale:Suitable for testing of hard sheet materials and surface layer hardened materials, also suitable for metal with hardness more than 70HRC such as tungsten carbide and hard alloy.
B scale:Suitable for testing of soft or medium hardness materials such as non-ferrous metals and their alloys, annealed steel or unhardened steel products.
C scale:Suitable for testing of the hardness of heat-treated steel products such as carbon steel, tool steel and alloy steel.
Technical Parameters
Model
|
HR-150A-Normal |
HR-150B-Heightened |
Measurement Range
|
20-88HRA、20-100HRB、20-70HRC |
|
Max height of the specimen
|
200mm |
400mm |
Hard resolution
|
0.5HR |
|
Test force
|
588.4N/60Kgf、980.7N/100Kgf、1471N/150Kgf |
|
Dimension
|
466mm×250mm×618mm |
548 x 326 x 1025mm |
Max distance between indentation center to machine wall
|
135mm |
160mm |
Net weight
|
80kg |
140kg |
Hardness tester specimen:
Specimen shall have a certain size and thickness, and shall ensure that the distance between the center of the adjacent indentation and the center of the indentation to the edge of the specimen is greater than 3 mm, and the minimum thickness of the specimen shall not be less than eight times the depth of the indentation.
After the test, there shall be no obvious deformation marks on the support surface of the specimen. The minimum thickness depends on the material and the load used. Refer to the minimum thickness table below.
Scale |
Hardness value (HR) |
Mini. thickness |
Scale |
Hardness value (HR) |
Mini. thickness |
A |
70 |
0.7 |
B |
80 |
1.0 |
|
80 |
0.5 |
|
90 |
0.8 |
|
90 |
0.4 |
|
100 |
0.7 |
B |
25 |
2.0 |
C |
20 |
1.5 |
|
30 |
1.9 |
|
30 |
1.3 |
|
40 |
1.7 |
|
40 |
1.2 |
|
50 |
1.5 |
|
50 |
1.0 |
|
60 |
1.3 |
|
60 |
0.8 |
|
70 |
1.2 |
|
67 |
0.7 |
SPECIMEN MINI. THICKNESS TABLE
Indication accuracy
1.Check the accuracy of the hardness tester regularly with the standard hardness block configured with this machine.
Wipe the workbench and standard block clean and test on the hardness block working surface, and never test on the support surface.
- If the indication value is large, in addition to the inspection in item 4 of this section, it should also check whether there is burr on the support surface of the standard hardness block. If there is burr, use oil stone to light it.
3.When testing at different positions of the standard block, the hardness block should be dragged close to the work surface, and it is strictly forbidden to take it off the workbench.
4.Adjustment of the indication of the hardness tester:If the above work is performed, the error of the hardness tester is still large, and the front and rear positions of the plate can be adjusted to meet the indication accuracy requirements.
To do this, loosen the two M3 screws on the front and rear of the adjustment plate and move the adjustment plate back and forth.
Note that when moving in the direction of the indicator, the value increases,otherwise the value decreases. After the adjustment is completed,the two M3 screws that have been loosened should be fastened.
- If users have other questions, they should contact the manufacturer in time to get the correct solution. Do not disassemble it yourself to prevent unnecessary damage.
Application range
Scale |
Hardness symbol |
Initial test force F0(kgf) |
Main test force F1(kgf) |
Total test force F(kgf) |
constant |
Rockwell hardness range |
Application specimen |
A
|
HRA |
10 |
50 |
60 |
100 |
20-88HRA |
Hard metal and hard alloy |
B |
HRB |
10 |
90 |
100 |
130 |
20-100HRB |
Non-ferrous metals and soft metals |
C |
HRC |
10 |
140 |
150 |
100 |
20-70HRC |
Heat treated structural steel, tool steel |
D |
HRD |
10 |
90 |
100 |
100 |
40-77HRD |
Surface hardened steel, thin steel |
F |
HRF |
10 |
50 |
60 |
130 |
60-100HRF |
Non-ferrous metal
|
G |
HRG |
10 |
140 |
150 |
130 |
30-94HRG |
Pearlite iron, copper nickel, zinc alloy |
Standards: GB/T 230.2, ISO 6508-2 and ASTM E18
-
*Subject:
-
*Message:Note:HTML is not translated!
-
*Name:
-
*E-Mail:
-
*Phone:
-
*Country name:
HR-150A ROCKWELL HARDNESS TESTER
Specifications
Measuring range: 20-88HRA, 20-100HRB, 20-70HRC
Test force: 588.4, 980.7, 1471N (60, 100, 150kgf)
Max. height of test piece: 170mm
Depth of throat: 135mm
Min. scale value: 0.5HR
Dimensions: 466 x 238 x 630mm
Weight: approx. 65kg
Standard accessories
Large flat anvil: 1 pc.
Small flat anvil: 1 pc.
V-notch anvil: 1 pc.
Diamond cone penetrator: 1 pc
1/16” steel ball penetrator: 1 pc.
Rockwell standardized block: 5 pcs.
HRD-150 MOTOR-DRIVEN ROCKWELL HARDNESS TESTER
HRD-150 electric Rockwell hardness tester is automatic to zero, the main test force is automatically loaded and unloaded, the lever is loaded, and the test process is automated.
This hardness tester is a practical semi-automatic hardness measuring instrument. In 1989, it won the National Quality Silver Award. It can be used to determine the Rockwell hardness values of ferrous metals, non-ferrous metals, non-metallic materials and products, and is widely used in factories, mines, research institutes and universities and colleges.
HRS-150 DIGITAL DISPLAY ROCKWELL HARDNESS TESTER
he spindle system of HRS-150 Digital Rockwell hardness test adopts the frictionless spindle structure. The application of the initial test force is controlled by the electromagnetic brake, thus improving the accuracy of the initial test force.
HRD-150H HEIGHTENED MOTOR-DRIVEN ROCKWELL HARDNESS TESTER
he surface of the tested part shall be smooth and clean, and shall not be contaminated with dirt, scale, back pit and significant processing
traces, the support surface of the test piece and the test bench should be clean and kept in good closeness. The thickness of the test piece is greater than about 10 times the depth of the indentation.
According to the shape and size of the test piece, choose the appropriate test bench. If the test piece is shaped, it can be designed and manufactured according to the specific geometry. (The company has a variety of test benches, users can choose as needed),so that the hardness test has an accurate indication.
200HR-150 ROCKWELL HARDNESS TESTER
200HRD-150. MOTOR-DRIVEN ROCKWELL HARDNESS TESTER
HRS-150T TOUCH SCREEN DIGITAL DISPLAY ROCKWELL HARDNESS TESTER
HRS-150Z PORTABLE ROCKWELL HARDNESS TESTER
HRSS-150 DIGITAL DISPLAY ROCKWELL SUPERFICIAL ROCKWELL HARDNESS TESTER
HRSS-150Z DIGITAL DISPLAY AUTOMATIC SUPERFICIAL HARDNESS TESTER
HRS-150X PORTABLE ROCKWELL HARDNESS TESTER
HRS-150ZF FULL AUTOMATIC ROCKWELL HARDNESS TESTER
HSRD-45 MOTOR-DRIVEN SUPERFICIAL ROCKWELL HARDNESS TESTER
HB-3000B BRINELL HARDNESS TESTER
200HB-3000 BRINELL HARDNESS TESTER
210HBS-3000 DIGITAL DISPLAY BRINELL HARDNESS TESTER
HBS-62.5 DIGITAL DISPLAY LOW LOAD BRINELL HARDNESS TESTER
HBS-62.5Z AUTO TURRET DIGITAL DISPLAY LOW LOAD BRINELL HARDNESS TESTER
HBS-3000T DIGITAL DISPLAY BRINELL HARDNESS TESTER
HBS-3000TA AUTO TURRET DIGITAL DISPLAY BRINELL HARDNESS TESTER
HBC HAMMER HITTING TYPE BRINELL HARDNESS TESTER
HBM-3000E GATE TYPE BRINELL HARDNESS TESTER
HV-5 LOW LOAD VICKERS HARDNESS TESTER
HV-5Z AUTO TURRET LOW LOAD VICKERS HARDNESS TESTER
200HV-5 LOW LOAD VICKERS HARDNESS TESTER
HVS-5 DIGITAL DISPLAY LOW LOAD VICKERS HARDNESS TESTER
HVS-5Z AUTO TURRET DIGITAL DISPLAY LOW LOAD VICKERS HARDNESS TESTER
MARX-5 DIGITAL DISPLAY VICKERS HARDNESS TESTER
MHVS-5 DIGITAL DISPLAY VICKERS HARDNESS TESTER
HV-10 VICKERS HARDNESS TESTER
HV-10Z AUTO TURRET VICKERS HARDNESS TESTER
HVS-30 DIGITAL DISPLAY VICKERS HARDNESS TESTER
HVS-30Z AUTO TURRET DIGITAL DISPLAY VICKERS HARDNESS TESTER
HBRV-187.5 BRINELL ROCKWELL VICKERS HARDNESS TESTER
HBRVU-187.5 BRINELL ROCKWELL VICKERS
HBRV-187.5D MOTOR-DRIVEN BRINELL ROCKWELL VICKERS HARDNESS TESTER
HBRV-187.5DHBRINELL ROCKWELL VICKERS HARDNESS TESTER
HBRV-187.5S DIGITAL BRINELL ROCKWELL VICKERS HARDNESS TESTER
HBRSV-250STP COMPURTER BRINELL ROCKWELL VICKERS HARDNESS TESTER
Standard Blocks
READOUT MICROSCOPE
INDENTER
HRS-150 Large Screen Digital Rockwell Hardness Tester
HRS-150 digital hardness tester adopts large LCD screen,Rockwell hardness scale and plastic rockwell scale can be selected by software.
Automatic load main test force,automatic display hardness valuve,various hardness values are automatically converted to each other.
The error of hardness value can be corrected by software input to make the hardness value more accurate.